Total System Rejuvenation 60-Point
Checklist
Condenser
- Check to make sure the condenser is level.
- Remove dirt, debris, and leaves from inside the condenser.
- Clean electrical components with compressed air or nitrogen.
- Verify that drainage holes in the bottom of the condenser are clear.
- Check for damaged fins; straighten if necessary.
- Clean condenser coils and exterior of unit.
- Check condenser fan mounting bracket or wires.
- Check and record condenser fan amp draw.
- Check the condenser fan motor for bearing wear.
- Lubricate the motor is applicable.
- Check the balance of condenser fan blade.
- Check and record coil temperature differential.
- Check refrigerant piping for kinks or bends.
- Check suction line insulation.
- Tighten and secure all electrical connections.
- Check for frayed, worn, or brittle wiring.
- Check for proper voltage; record.
- Check the outdoor electrical disconnect.
- Check fuse holders and verify correct fuse sizes.
- Verify capacitor microfarad rating.
- Check crankcase heater operation.
- Check contactor contacts and operation.
- Check electrical relays.
- Check high and low-pressure controls.
- Check and record superheat and sub-cooling.
- Check compressor terminals.
- Check and record compressor amp draw.
- Check for high temperature differential across refrigeration components.
- Check and record operating temperatures and pressures.
- Check for adequate refrigerant change.
- Check for refrigerant leaks.
- Check to make sure refrigerant piping is secure and not vibrating.
- Check for and replace missing screws, bolts, and hardware.
Evaporator
- Check and spray/brush the evaporator coil.
- Check the coil for air restriction.
- Check the TXV for proper location and contact with the suction line.
- Check and secure suction line insulation.
- Check capillary tubing for kinks.
- Check and clean the condensate pump, including the safety switch.
Furnace, Air Handler, Controls
- Check and clean the blower assembly.
- Check the air filter; clean or replace as necessary.
- Clean the inside compartments of the air handler.
- Check the blower motor; lubricate is applicable.
- Check and record blower motor amp draw.
- Check blower belt and tension, if applicable.
- Check fan center and cooling relay.
- Clean the exterior of the unit.
- Tighten and secure unit electrical connections.
- Check for frayed, brittle, or worn wiring.
- Check and record temperature drop across the evaporator coil.
- Check for and replace missing screws, bolts, and hardware.
- Check thermostat electrical connections.
- Make sure the thermostat is level.
- Check thermostat accuracy.
Ductwork
- Verify that all registers are open.
- Check the system’s external static pressure.
- Check for proper airflow.
- Verify proper duct sizes.
- Check ductwork for air leakage.
- Check for any missing or loose insulation.